Tel:+86-13338149279E-mail:[email protected]

Cummins powered open type diesel generator with grey alternator

Cummins

Cummins-powered diesel generator sets from about 10 kW to over 1000 kW, built on one engine and control standard so a mixed fleet shares spares and training.

Request Motor Matrix

Product Detail

One engine standard across a fleet that spans 10 kW to over 1000 kW

Operating companies that run more than one set usually inherit a mixture: a small unit at a gatehouse, a mid-size machine in a workshop, a large one for the main load. Each brings its own filters, its own panel logic and its own training. Consolidating on Cummins-powered machines removes part of that burden, because the engine standard is understood by mechanics in most markets and the same control concept runs through the range.

This series covers that span from a small three-phase set up to machines above 1000 kW, with the radiator, panel and enclosure chosen for the climate and the duty your site presents.

  • Engine platformCummins diesel
  • Output windowFrom around 10 kW up to and beyond 1000 kW
  • Frequency and speed50 Hz at 1500 rpm; 60 Hz at 1800 rpm available
  • Output400/230 V three-phase as standard; 440 V to order
  • Build formsOpen skid, canopy or container depending on the installation point

Specification sheet for a Cummins-powered set

ItemConfiguration
Genset typeDiesel generator set powered by a Cummins engine
EngineCummins diesel, water-cooled; model matched to the required rating
Output windowSmall single-unit sets from about 10 kW through to machines above 1000 kW, including the 500 kW class
Frequency and rated speed50 Hz at 1500 rpm; 60 Hz at 1800 rpm confirmed per order
Voltage and phase400/230 V, 3-phase, 4-wire; 440 V three-phase to order
Power factor0.8 lagging
AlternatorBrushless, single-bearing, self-excited; frame selected from the rating and the load type
Control panelManual start, or automatic start with ATS interface; synchronising panel for multi-unit plants
CoolingRadiator sized for the ambient temperature of the destination, not for a temperate default
Fuel tankBase-frame tank; the day-tank arrangement is added where longer autonomy is needed
EnclosureOpen skid for plant rooms; canopy or container for outdoor and boundary positions
Sound levelCanopy sets are commonly specified in the 65 to 75 dB(A) range at 7 m; confirm for the selected canopy
Dimensions and weightConfirmed per model on the quotation
PackingStrong wooden case with waterproof cloth
Typical dutyWorkshops and factories, telecom and commercial standby, pumping, rental fleets, plant rooms
Small Cummins diesel generator with control panel on the left
Panel and instrumentation on a finished set. The same control concept is used across the range, so a mechanic trained on one machine can read the next.
Multiple Cummins diesel generators in production workshop
Sets from this series on the works floor, coupled on their base frames and cased for shipment after testing.

What consolidating on this platform gives a buyer

  1. One engine standard for the whole site. Filters, belts and typical wear parts follow one family rather than several, which simplifies stock holding.
  2. Wide rating coverage from the same supplier. A 10 kW machine for a guard house and a 500 kW machine for a factory can be quoted, built and supported as part of one fleet.
  3. Radiators chosen for the destination climate. Sets going to hot inland sites are not ordered with a temperate-climate cooling package by default.
  4. Panel behaviour that does not vary by size. Start, stop, alarm and ATS logic stay recognisable as the rating rises, which shortens operator training.
  5. Enclosure or open frame for the same machine. If a site plan changes, the set can be supplied in the build form the installation point requires.
  6. Fleet-level parallel options. Where load grows, machines can be brought under synchronising control instead of being replaced.

The works that assembles these sets

Jiangsu Qingzhiteng Power Equipment Co., Ltd produces diesel and gas generator sets in Yangzhou, Jiangsu, with an inland diesel range of 3 kVA to 3000 kVA and a marine range of 12 kW to 500 kW. Sets with ATS, low-noise canopies, container units, parallel operation and remote monitoring are all assembled in the same plant, and the company exports to more than 80 countries on five continents.

Assembly and test sequence

  1. The engine and alternator specified in the order are received and checked in.
  2. The two units are coupled and aligned on the base frame.
  3. Cooling, fuel and exhaust circuits are assembled and leak-tested.
  4. The panel is wired and the harness is continuity-checked against the drawing.
  5. The set runs on the test bench and its voltage, frequency and protection settings are verified.
  6. The enclosure, lifting points and paint are completed.
  7. The unit is cased with waterproof cloth and dispatched with the packing list.

Duties served by this platform

Factory and workshop standby, Southeast Asia

A plant with mixed three-phase loads needed standby power sized on motor starting current rather than on the running total. The frame and alternator were set from the equipment list the buyer supplied.

Commercial building, Middle East

The requirement was automatic standby for lifts and lighting in hot ambient conditions, so the cooling package and panel were specified against the local temperature.

Rental fleet, Africa

An operator standardised on one engine family across units of different sizes to keep spares simple, and the fleet was supplied on that basis.

Questions buyers ask about this range

Which Cummins-powered ratings can you build?

Small three-phase sets from about 10 kW, mid-size machines around 40 kW to 200 kW, and larger units in the 500 kW class and above. Tell us the rating or the load and we will confirm the engine model, alternator frame and panel for that combination.

Do you supply 60 Hz versions?

Yes, 60 Hz at 1800 rpm is built on request alongside the 50 Hz at 1500 rpm range. State the destination country and the required voltage and frequency when you enquire.

Can the set work with an ATS and remote monitoring?

Both are available and are usually specified together for unattended sites. Describe the changeover arrangement and what you need to see remotely, and the panel will be configured accordingly.

How do I compare two offers for the same rating?

Put the engine model, alternator make and frame, panel functions and the enclosure build form side by side, and check that the radiator suits your ambient temperature. Two machines can carry the same kVA figure and still differ in every one of those items.

What are the MOQ, lead time and payment terms?

These depend on the rating, quantity, destination and payment method and are set out in the quotation. Send the quantity and the port and we will quote on that basis.

Other engine platforms in the same works include the SDEC series and the Perkins series; the full product range shows the enclosure and container build forms.

Send the load list with the rating you have in mind

Tell us the required output, the equipment being supplied, the destination ambient temperature, the voltage, frequency and phase, whether an ATS or canopy is needed, the quantity and the port. We will confirm the engine and alternator combination for that requirement.

Request a Cummins series selection

Keywords used on this page: cummins 500kw generator, 40kw cummins generator, cummins 10kw generator

Related Products

Request Motor Matrix

β–Έ Submit Inquiry

FORM Β· REV.1
CONTACTUS